1.
Chinese Medical Equipment Journal ; (6)2004.
Article in Chinese | WPRIM | ID: wpr-592390

ABSTRACT

Objective To explore problems of chemical indicative cards and adhesive tapes in the disinfection,and find out some measures for improving the sterilizing effect of the pressure steam sterilizer.Methods 100 stoves of time with various package,dressing and storage tank were disinfected by pulse pressure steam sterilizer and chemical indicative cards of 3M1250 pressure steam sterilizing package at the same pressure,time and temperature.All test wraps were examined and the real conditions were recorded after the sterilization.Results The discoloration of chemical indicative cards in 10 test wraps was not standard before the measures were taken.While after that,it didn't occur again.Conclusion The nonstandard discoloration of chemical indicative cards of 3M1250 pressure steam sterilizer is influenced by condensed water of steam during the steam sterilization.In order to make the chemical indicative cards change into standard black,the accurate using of chemical indicative cards,the standard stuff package and correct using of disinfector are required.

2.
Chinese Medical Equipment Journal ; (6)2003.
Article in Chinese | WPRIM | ID: wpr-590375

ABSTRACT

Operation rules of sterilizing are put forward.Responsible persons with working licenses are selected.The cleanout,packing,loading of pre-sterilized goods are standardized.Sterilizing effects(physical monitoring,chemical monitoring,biological monitoring,B-D test) are inspected.Requirements in maintenance and metrology test are raised.The content and methods for quality control of sterilized goods by using decontamination device are introduced systematically.It is instructive to enhance decontamination quality and lower infection rate in hospitals.

3.
Chinese Medical Equipment Journal ; (6)1993.
Article in Chinese | WPRIM | ID: wpr-594724

ABSTRACT

Objective To strengthen the concepts of safety and protection on equipment cleaning in supply room. Methods Through the analysis of risk factors at the time of cleansing, from goods classification to standard cleaning operation means, the awareness of staff that cleans equipments was improved. Results By amending cleaning ways and practising standard prevention, the dangers that equipment scavenger may cause to themselves in the work were decreased. Conclusion The safety control system can be perfected and the quality safety of medical apparatus is ensured and prevents the infectious disease in the hospital.

4.
Chinese Medical Equipment Journal ; (6)1993.
Article in Chinese | WPRIM | ID: wpr-591903

ABSTRACT

Objective To discusse the quality control of regenerated medical instrument.Methods The disinfection effect was evaluated through the effective basic quality control of washing.Results Without one standard evaluation method for medical instrument disinfection so far,the quality control can only be enhanced by executing the Technical Standard For Disinfection.Conclusion By effective quality control,the management method of washing is improved and the quality is enhanced,thus guaranteeing the safety utility of regenerated medical instrument.